top of page

F2 Material distributor tripped

Possible cause:

The material distributor and the conveyor system have stopped.
The over-current relay of the material distributor motor has tripped.
The revolution guard of the material distributor has stopped the material distributor and the conveyor system.

Rectification:

Check that the propeller of the material distributor is not obstructed by waste material. Clear the propeller if necessary. Don’t restart the material distributor until this is done.
Check the V-belt tension of the material distributor.
Reset the over-current relay located in control cabinet. The electrical diagram is in Appendix.
If the fault recurs check the over-current relay, the windings of the motor and the motor cables for signs of short-circuiting, wear or damage.
Lethal voltage. Moving parts. Only qualified personnel (12, 15, 19)

Presona UK Ltd

Unit 11 & 12 Blake Mill Business Park

Bridgwater

Somerset

TA6 5LT

(+44) 01278 444 527

Mon - Fri  08:00 - 17:00

Bank Holiday's - CLOSED

Reg No. 6715876

Swoosh HD no whiteR.png

© 2008 - 2024 Presona UK Rights Reserved